Description |
_AcStructure |
Archiving/Compression.
The parameters of set compressions of AC types are saved in an
internal data point of type _AcStructure |
_AlertClass |
Alert
classes. There is an own internal data point type to communicate
easier with the alert classes, which are addressed via a data
point variable. WinCC OA
provides five alert classes by default. These alert classes are
configured as _alert_class configs in the internal data point
types. |
_AlertSaveRestore |
Data
backup in WinCC OA.
The names of the target directories are kept for management of
stored data, the name of the source directory when importing ,
the limits of the time interval during which the data is contained
in the directory, status bits for improvement of the import
process and other similar things- all this information is saved
in internal data points. _AlerSaveRestore contains the settings
for the alarm history. |
_ArchivControl |
Data
backup in WinCC OA.
Contains the settings for the alarm history. (Archive control
panel) |
_ArchivDir |
Data
backup in WinCC OA |
_Archive |
Data
backup in WinCC OA |
_ArchiveManager |
Data
backup in WinCC OA.
Contains only one element with the list of data point identities
(dyn_dpid). |
_AsciiConfig |
ASCII
Manager panel. In order to save different configurations,
data points of type _AsciiConfig are created. The name of the
configuration, which can be set in the panel, does ,however, not
correspond to the data point name. This is assigned automatically. |
_AsciiManager |
ASCII
Manager. The file name of the ASCII file is the only element
of the data point. |
_ChildPanel |
Data point type
for opening a childpanel (see ChildPanelOn()
etc.) |
_Config |
Central settings.
This data point type contains general configurations and saves
settings that are made centrally , for example, settings for Cluttering/Decluttering
(Data point _Config) from the system management panel. |
_Connections |
This data point
type contains the connections of the Dist
manager (for _DistConnection and _DistConnections2 data
points see Distributed
systems) as well as the connections in redundancy cases (for
data point _Connections and _Connections2 see Redundancy) |
_CtrlDebug |
CTRL
debugger . CTRL debug commands and their return information
between the CTRL debugger and the manager to be debugged are exchanged
via this data point type. |
_DataBgManager |
Data
backup in WinCC OA.
The data background manager supports the Data
Manager in case of non time critical operations. There
are two data points. |
_DataManager |
Data
backup in WinCC OA.
For configuration of the data manager,
of the data backup etc. |
_DataSaveRestore |
Data
backup in WinCC OA.
The stored data of the value history, which is available
for WinCC OA,
can be subject to cyclic handling per data point element. You
can for example define that the data of an element is exported
at specific intervals. This way system resources are released
without loosing data for later analyses. |
_DataSet |
Data
backup in WinCC OA.
The stored data of the value history, which is available for WinCC OA, is saved in chronological
sorted data sets. This is made clear by the directory names which
are assigned automatically. In order to administer data sets you
can register when the last change of a data set took place, whether
data sets are swapped out or deleted etc. |
_DiskSpaceCheck |
Online
Backup. There is data point of type _DiskSpaceCheck for each
hard disk that should be included in the check. The associated
DP _ArchiveDisk or _ArchivDisk_2 is created as standard. The configuration
takes place via the panels for monitoring
the hard disk. |
_Dist |
Distributed systems.
The internal data point _DistConnections (or _DistConnections_2
at redundancy) of type _Dist contains the state of all distribution
manager connections to foreign systems. There are two elements
update (bool) and updateTimes (dyn_uint). |
_DistIdExchange |
Distributed systems.
Contains the data point elements _DistIdExchange.send (dyn_time)and
_DistIdExchange.rcv (dyn_time) which save the time of balancing
when changes were sent or received. These data point elements
are initialized with 1.1.1970 when starting the system. |
_DpeMonitor |
DPE monitor panel.
Contains the chosen data points as dyn_string in two data point
elements and the name of the configuration. |
_DpGroups |
Data
point groups Contains the created data point groups (by default
7) |
_DriverCommon |
ComDR..
Internal data point type of the general driver. |
_DynamicDatapoints |
Mass
configuration. This data point type contains a data point
for each DPT, which contain a master data point, in the system.
The configured PowerConfigs and the dynamic attributes are saved
in the elements of these internal data points. |
_Event |
Licensing.
The data point type contains three elements. Via this elements
the licenses of WinCC OA
are checked. |
_Iec |
IEC
driver . The user has to create a data point of type _Iec
for each connection between the driver and the control |
_IecConnections |
IEC
driver. Connections can be assigned via this data point
type. |
_IS_ArchivGroup |
Information
server contains the configurations of the used archive groups.
The DP name is composed automatically of the "IS_ArchiveGroup_"
text and of a consecutive number |
_IS_Control |
Information
server serves for activating and deactivating of archive groups
(see function IS_ControlExitWorkFunction in IS.ctc) as well as
for stopping and restarting of the IS archive groups (see function
IS_ControlWorkFunction in IS.ctc) |
_IS_Database |
Information server
contains the configurations of the used DBs. The DP name
is identical to the DB name. If an ODBC-DB is used, the DB name
is the DSN name. If the DB is a MS Access database, the file name
is used as DP name WITHOUT the extension"mdb". |
_IS_Table |
Information server
contains the configurations of the used tables. The DP
name is composed automatically: DB name + "_" + table
name (defined during the configuration) |
_IS_TableType |
Information
Server contains the configurations of the used user-defined
tables. The DP name is composed of IS + "_" + table
type name for the user-defined tables. |
_Layers |
The
layers sheet. The command for showing and hiding of panel
levels can be executed interactive via menu or tool bars or via
sending a data point. |
_Managers |
Authorizations.
The workstation authorizations are set via this data point type. |
_MediaConfig |
Data
backup in WinCC OA.
The data point type _MediaConfig saves the different configurations
which were created in the ArchivControl panel with the Configurations
button (see Archive
control panel). |
_MemoryCheck |
Online
Backup. The configuration of the virtual memory monitoring
takes place via an internal data point. The type of the
data point is _MemoryCheck. There is one data point _MemoryCheck
and one data point _MemoryCheck_2 by default. |
_Module |
This data point
is composed of only two elements ManNum and ModuleName. |
_ModuleOn |
There is an own
data point type for opening a module. Each UIM registers a data
point of this type at the Event Manager
when starting. |
_OPCGroup |
OPC
driver. An internal data point of type _OPCGroup has to exist
for each group that should be used in the OPC server. This data
point has to be created before the group is created in the server.
This means before the first data point with an address that is
included in this group, is configured (see OPC
group panel). |
_OPCServer |
OPC
driver. The properties of a server are set via the server
data point and the status information of the server is provided.
The values are displayed in the OPC server panel (see OPC
server panel). |
_Panel |
panel.ctl
The opening and closing of panels via another panel takes always
place by sending a data point. There is a difference between opening
a root panel and opening a child panel. There are specific data
point types for opening and closing of panels. The elements of
these data point types contain all data that is needed for opening
and closing of panels. |
_PanelTopologie |
Panel
topology/Group alerts: Contains the configuration of the created
panel topology. |
_Printer |
Print
panels. In order to send panel printouts via different printers,
the information of the printers available in the network has to
be transferred to the control system. The printer data is saved
in own data points. |
_PrintPanel |
Print
panels. Panels that are opened via another panels can also
be printed. This means that the panels can be printed with all
opened child panels. The command for printing is executed via
a panel by sending a data point. |
_PTPanelOn |
Panel
topology/Group alerts: This data point type contains the current
settings of the direct selection in the panel topology. (See
Configuration of the direct selection). The settings consist
of a data point _PTPanelOn and of its element fileName, of the
panels and of the information if the assigned button is active. |
_Rcp |
Recipes.
There are two internal data point types available for recipes.
New recipe types are created as data points of type _Rct.
New recipes are created as data points of type _Rcp. |
_Rct |
Recipes.
There are two internal data point types available for recipes.
New recipe types are created as data points of type _Rct.
New recipes are created as data points of type _Rcp. |
_RDBArchive |
This data point
type contains the settings for archiving using the relational
database. See also RDB archiving. |
_RDBArchiveControl |
This data point
type contains the error number of the last error and the name
of the data point element which has triggered this error. See
also RDB archiving. |
_RDBArchiveGroups |
This data point
type holds the settings of the archive groups See also Setting
archive group parameters. |
_RDBUserDefinedTemplates |
This data point
type holds the settings to the user-defined templates. See also
User defined archive groups. |
_ReduManager |
Redundancy.
Contains the data points _ReduManager and _ReduManager2 with the
status of connections. |
_RK512 |
RK512
driver. The driver notifies the WinCC OA
system of its status via an internal data point of type _RK512
and allows the system to change the settings of the driver at
runtime. |
_RootPanel |
panel.ctl
In order to open and close panels all elements of the concerned
internal data point within a dpSet()
command have to be assigned. For root panel these data
points are _RootPanelOrigOn (Opening in original size) and _RootPanelOn
(opening in size of the existing panel) |
_SilentPrint |
User
interface. Consists of the element unsigned SilentPrint
only. The status of the current or last print job can be found
in the internal data point _SilentPrint of type _SilentPrint.
|
_Simulator |
Simulator
driver. You can create simulator data points with the aid
of the internal data point type _Simulator. WinCC OA already contains
three predefined data points _Simulator_1, _Simulator_2 and _Simulator_3.
The name of the simulation file can be defined on the FileName..original
leaf. |
_SSI_Alive |
SSI
driver . The data points have to be named _SSI_Alive_<num>.
<num> indicates the driver number. The alive
monitoring between KE/ET and driver is realized via pulse
commands. |
_SSI_DaDf |
SSI
driver . The assignment between data formats and data types
is defined in the data point _SSI_DaDf_Table. The data point has
32 leaves of type unsigned for the different data types. Not allocated
data types have the initialization value -1. |
_SSI_ImpulseType |
SSI
driver . The switch time can be defined in two ways. A switch
time within the system, which is used for all commands, will
be sufficient for the most commands. If other switch times should
be configured for single commands, these can be configured in
the data point _SSI_Impulse_Times (the data point contains a dynamic
field of bit patterns which allow the definition of desired switch
times)the easiest way is to define the time in the pulse time
panel of the peripheral address panel. |
_SSI_SysAll |
SSI
driver . It might be necessary to send a message to all system
components (target component number 255). For this case there
is an internal data point (and it has the type _SSI_SysAll) which
is assigned to the component 255 and which has data point leaves
for the outgoing messages. Each driver supports two data points
of this type. The first is called _SSI_ALL_<KE/ET region number>_<KE/ETcomponent
number> and is assigned to the driver that is connected with
the specified KE/ET. The second is called _SSI_ALL_255_255
and is used by all SSI drivers in the system. |
_SSI_SysMgm |
SSI
driver. Incoming messages are intercepted by the driver because
of the data format (0 for system and 100 for sorting messages)and
are represented on the leaves of a component specific internal
data point (of type _SSI_SysMsg) of WinCC OA.
Such data point has to be created for each component in the system.
The name of the data point is composed of the region number and
of the component number |
_Statistics_Connections |
WinCC OA messages . The
data point type _Statistics_Connections is composed of counters
(leaves). The leaves contain the amount of the messages that were
sent in the last interval (SndTotal) and the amount of messages
that were received (RcvTotal) as well as the total number of messages.
By default, data points are intended for messages between event
0 and 4 CTRL manager, 4 user interfaces, 4 drivers, 1 dist manager,
1 data manager, 1 redu manager and 2 events (0, 128). For further
driver or UIs additional DPs have to be created. |
_Statistics_DataConfig |
WinCC OA messages. The
event manager, the data manager and all drivers write the number
of configs which they administer into a data point of type _Statistics_<Man>Configs
, for example, _Statistics_Configs_Event_0. If a config or a DP
is created, the change is saved in the data point first when the
interval of the leaf SecsToRefresh has expired. This data point
contains only the _archive config. |
_Statistics_DriverConfigs |
WinCC OA messages. The
event manager, the data manager and all drivers write the number
of configs which they administer into a data point of type _Statistics_<Man>Configs
, for example, _Statistics_Configs_Event_0. If a config or a DP
is created, the change is saved in the data point first when the
interval of the leaf SecsToRefresh has expired. This data point
contains the elements _address, _cmd_conv, _msg_conv, _smooth.
These elements are relevant for the driver. |
_Stat_event_0 |
The data point
element saves the total performance (the amount of all Event
Manager connections) per message. |
_Statistics_EventConfigs |
WinCC OA messages. The
event manager, the data manager and all drivers write the number
of configs which they administer into a data point of type _Statistics_<Man>Configs
, for example, _Statistics_Configs_Event_0. If a config or a DP
is created, the change is saved in the data point first when the
interval of the leaf SecsToRefresh has expired. Furthermore, the
number of DPs and DPTs is stored here. |
_Statistics_Msg |
WinCC OA messages. The
data point type _Statistics_Msg contains the possible message
categories. |
_Statistics_Refresh |
WinCC OA messages. The
data point type _Statistics_Refresh contains the data point _Statistik_Connections_Refresh
with the element SecondsToRefresh. |
_SumAlertGeneral |
Panel
topology/Group alerts. Contains the configurations of the
priority ranges as well as the fixed parameters of the future
group alerts. |
_SumAlertPanel |
Panel
topology/Group alerts. Contains the configurations of the
priority ranges as well as the fixed parameters of the future
group alerts. A data point with all priority ranges is created
for each panel in the topology. The naming of the DP looks like
following "Panelname" + _1 |
_System |
Authorizations.
Actions like creating, changing and deleting of data point types,
data points, alias and manipulations of the authorization config
are defined via the data point element (_System.Auth) |
_TimedFunc |
You can start user-defined
CTRL functions, time-dependent and configured via a data point
with timedFunc(). Start time, interval and the remaining configuration
take place via data points of the internal data point type "_TimedFunc". |
_Ui |
Module VISION. An
internal data point type for the user interface. Contains information
of the panels, layers etc. Each manager corresponds to this kind
of data point. |
_Users |
Authorizations.
Users can have a name, an identification number, a password
and an authorization code in WinCC OA.
|
_ValueArchive |
History
DB The archive parameters are administered as elements
of the archive data point (_ValueArchiv). There are pure parameters
and actions. Only the archive is notified of the parameters. Actions
trigger procedures in the archive process. These are then reported
via other DPEs of the archive data point. This chapter describes
the "simple" archive parameters. |
_ValueArchivMedia |
History
DB . This data point type contains the settings for the data
transfer at archive change and release of archives. |
_VarTrend |
Variable
trend. This data point type contains the settings that are
specified when configuring a variable trend. The appropriate data
points are _VarTrend0000 and _VarTrend9999. Further data
points are created for each trend configuration. |
_VarTrendOpen |
Variable
trend. This data point type contains user interface, panel
name and configuration that should be opened. The appropriate
data point is _VarTrend0pen. |