content.gif menu.gif basics.gif

OPC UA Status Codes

The following status codes exist in OPC UA. These have to be mapped to WinCC OA user bits (see also "Status Mapping" in chapter Configuration of the Servers).

OPC UA detail status

Actual value

Description

Good_Clamped

0x00300000

The value written was accepted but was clamped.

Good_Overload

0x002F0000

Sampling has slowed down due to resource limitations.

Uncertain

 

The value is uncertain but no specific reason is known.

Bad

0x80010000

The value is bad but no specific reason is known.

Bad_BrowseDirectionInvalid

0x804D0000

The browse direction is not valid.

Bad_BrowseNameInvalid

0x80600000

The browse name is invalid.

Bad_ContentFilterInvalid

0x80480000

The content filter is not valid.

Bad_ContinuationPointInvalid

0x804A0000

The continuation point provide is longer valid.

Bad_DataEncodingInvalid

0x80380000

The data encoding is invalid.

Bad_DataEncodingUnsupported

0x80390000

The server does not support the requested data encoding for the node.

Bad_EventFilterInvalid

0x80470000

The event filter is not valid.

Bad_FilterNotAllowed

0x80450000

A monitoring filter cannot be used in combination with the attribute specified.

Bad_FilterOperandInvalid

0x80490000

The operand used in a content filter is not valid.

Bad_HistoryOperationInvalid

0x80710000

The history details parameter is not valid.

Bad_HistoryOperationUnsupported

0x80720000

The server does not support the requested operation.

Bad_IndexRangeInvalid

0x80360000

The syntax of the index range parameter is invalid.

Bad_IndexRangeNoData

0x80370000

No data exists within the range of indexes specified.

Bad_MonitoredItemFilterInvalid

0x80430000

The monitored item filter parameter is not valid.

Bad_MonitoredItemFilterUnsupported

0x80440000

The server does not support the requested monitored item filter.

Bad_MonitoredItemIdInvalid

0x80420000

The monitoring item id does not refer to a valid monitored item.

Bad_MonitoringModeInvalid

0x80410000

The monitoring mode is invalid.

Bad_NoCommunication

0x80310000

Communication with the data source is defined, but not established, and there is no last known value available.

Bad_NoContinuationPoints

0x804B0000

The operation could not be processed because all continuation points have been allocated.

Bad_NodeClassInvalid

0x805F0000

The node class is not valid.

Bad_NodeIdInvalid

0x80330000

The syntax of the node id is not valid.

Bad_NodeIdUnknown

0x80340000

The node id refers to a node that does not exist in the server address space.

Bad_NoDeleteRights

0x80690000

The Server will not allow the node to be deleted.

Bad_NodeNotInView

0x804E0000

The nodeToBrowse is not part of the view.

Bad_NotFound

0x803E0000

A requested item was not found or a search operation ended without success.

Bad_NotImplemented

0x80400000

Requested operation is not implemented.

Bad_NotReadable

0x803A0000

The access level does not allow reading or subscribing to the Node.

Bad_NotSupported

0x803D0000

The requested operation is not supported.

Bad_NotWritable

0x803B0000

The access level does not allow writing to the Node.

Bad_ObjectDeleted

0x803F0000

The object cannot be used because it has been deleted.

Bad_OutOfRange

0x803C0000

The value was out of range.

Bad_ReferenceTypeIdInvalid

0x804C0000

The reference type id does not refer to a valid reference type node.

Bad_SourceNodeIdInvalid

0x80640000

The source node id does not refer to a valid node.

Bad_StructureMissing

0x80460000

A mandatory structured parameter was missing or null.

Bad_TargetNodeIdInvalid

0x80650000

The target node id does not refer to a valid node.

Bad_TypeDefinitionInvalid

0x80630000

The type definition node id does not reference an appropriate type node.

Bad_TypeMismatch

0x80740000

The value supplied for the attribute is not of the same type as the attribute's value.

Bad_WaitingForInitialData

0x80320000

Waiting for the server to obtain values from the underlying data source.

 

 

page_top.gif

V 3.11 SP1

Copyright ETM professional control GmbH 2013 All Rights Reserved